null

Amprobe 30XR-A Auto Ranging Digital Multimeter with VolTect Non-Contact Voltage Detection

(No reviews yet) Write a Review
MSRP: $112.99
$91.39
(You save $21.60 )
SKU:
30XR-A
UPC:
095969365369
Availability:
IN STOCK
Weight:
2.00 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added

Product Overview

Amprobe 30XR-A Auto Ranging Digital Multimeter with VolTect Non-Contact Voltage Detection

For non-contact voltage testing, Amprobe 30XR-A Digital Multimeter offers Voltect™ non-contact voltage technology built into the 30XR-A along with a full complement of measurement functions.

  • Non-contact voltage detector
  • Separate door for easy battery and fuse access
  • Manual ranging; display: 3-1/2 digit LCD, 1999 counts
  • Display update rate: 2.5/sec, nominal
  • Power battery: 9 V NEDA 1604, JIS 006P, IEC 6F22
  • Operating temperature: 0 °C to 45 °C at < 70 % R.H.
  • Storage temperature: -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
  • Low battery indication
  • Overrange indication
  • Min/max and data Hold

What’s Included

  • 30XR-A
  • Test leads (TL36A)
  • 9 V battery (installed)
  • Magne-Grip™ Holster with magnetic hanging strap
  • Spare fuse

Specifications

FEATURE 30XR-A
DC Voltage 200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V
AC Voltage 200.0 mV 2.000 V, 20.00 V, 200.0 V, 500 V
DC Current 200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A
AC Current 200.0 µA 2.000 mA, 20.00 mA, 200.0 mA, 10 A
Resistance 200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO
Continuity
Diode
VolTect™ Non-Contact Voltage Detection
Capacitance
Frequency
Temperature
Duty cycle
Logic test
Inductance
dBm
Specifications
DC Voltage ranges 200 mV, 2 V, 20 V, 200 V, 600 V
DC Voltage accuracy All ranges: ± (1 % rdg + 1 dgt)
DC Voltage resolution 100 µV
DC Voltage input impedance 10 MO
AC Voltage (45 Hz to 500 Hz) ranges 200 mV, 2 V, 20 V, 200 V, 600 V
AC Voltage (45 Hz to 500 Hz) accuracy All ranges: ± (1.5 % rdg + 4 dgts)
AC Voltage (45 Hz to 500 Hz) resolution 100 µV
AC Voltage (45 Hz to 500 Hz) input impedance 10 MO
DC Current ranges 200 µA, 2 mA, 20 mA, 200 mA, 10 A
DC Current accuracy 200 µA to 200 mA ranges: ± (1.5 % rdg + 1 dgt)

10 A range: ± (2.0 % rdg + 3 dgts)

DC Current resolution 0.1 µA
DC Current voltage burden (max) 200 µA range: 1 mV/µA

2 mA range: 100 mV/1mA

20 mA range: 13 mV/1 mA

200 mA range: 4.6 mV/1 mA

10 A range: 40 mV/1 A

AC Current (45 Hz to 500 Hz) ranges 200 µA, 2 mA, 20 mA, 200 mA, 10 A
AC Current (45 Hz to 500 Hz) accuracy 200 µA to 200 mA ranges: ± (2.0 % rdg + 4 dgts)

10 A range: ± (2.5 % rdg + 4 dgts)

AC Current resolution 0.1 µA
AC Current voltage burden See DC Current
Non-contact voltage detector (NCV) AC volts 70 to 600 V AC
Non-contact voltage detector (NCV) Red LED and Audible Indicator

Reviews

(No reviews yet) Write a Review