Product Overview
Amprobe ACD-10 PLUS 600A Clamp Multimeter
The Amprobe ACD-10 PLUS clamp multimeter has thinner jaws than standard digital clamp multimeters (only 0.4″/10mm thick) allowing access to tight measurement areas and still handles conductors up to 1.0 (25mm).
It combines the convenience and flexibility of an AC/DC current clamp meter with the most frequently used digital multimeter functions, including ac/dc current and voltage, capacitance, and frequency.
- Measures AC and DC voltage to 600V and AC current to 600A to handle residential/commercial and small industrial applications
 - Thin jaws, only 10mm (0.4″) thick make it easier to maneuver between tightly packed conductors
 - Measures frequency, resistance, and capacitance
 - Features continuity beeper to quickly find opens and shorts
 - Accommodates conductors up to 1.0″ (25mm) in diameter
 - Auto ranging saves time by instantly selecting correct range
 - Auto power off to conserve battery life
 - Rubber over-molded case absorbs shock
 - Includes test leads, battery (installed), soft carrying pouch, and users manual
 
What’s Included
| Description | |
 Included Accessories: Test leads, battery (installed), soft carrying pouch, users manual  | 
Specifications
| FEATURE | ACD-10 PLUS | ACD-10 TRMS-PLUS | 
| True-rms | – | • | 
| AC Voltage | 4.000 V, 40.00 V, 400.0 V, 600 V | |
| DC Voltage | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600 V | |
| AC Current | 40.00 A, 400.0 A, 600 A | |
| Resistance | 400.0 µΩ, 4.000 Ω, 40.00 Ω, 400.0 Ω, 4.000 MΩ, 40.00 MΩ | |
| Capacitance | 500.0 nF, 5.000 F, 50.00 CF, 500.0 µF, 3000 µF | |
| Frequency | 40 Hz → 400 Hz with Jaw, 10 Hz → 100 kHz with test leads | |
| Temperature | – | – | 
| Dual displays | – | – | 
| Micro Amps | – | – | 
| Accommodates conductors | up to 1.0″ (25 mm) in diameter | |
| Specifications | |
| Display: | 3-3/4 digits 4000 counts LCD display | 
| Update rate: | 3 per second nominal | 
| Polarity: | Automatic | 
| Operating temperature: | °C to 40 °C; < 80% RH for temperature up to 31 °C decreasing linearly to 50% RH at 40 °C | 
| Altitude: | Operating below 2000m; Indoor use | 
| Storage temperature: | -20 °C to 60 °C, < 80% RH (with battery removed) | 
| Temperature coefficient: | nominal 0.15 x (specified accuracy)/°C @(0 °C ~ 18 °C or 28 °C ~ 40 °C) | 
| Low battery: | Below approx. 2.4V | 
| Power supply: | 3V coin battery IEC-CR2032 | 
| Power consumption: | 2.8 mA typical except that 3.3 mA typical for ACA function | 
| APO timing: | Idle for 30 minutes | 
| APO consumption: | 5 µA typical | 
| Jaw opening conductor diameter: | max 26 mm | 
| Special features: | 30ms Max Hold; Data Hold; Relative Zero mode |