What’s Included
- 33XR-A
- Test leads with threaded alligator clips
- 9 V battery (installed)
- Magne-Grip™ Holster with magnetic hanging strap
- Temperature adapter
- Type K thermocouple probe
- Spare fuse
Specifications
| FEATURE | 33XR-A |
| DC Voltage | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
| AC Voltage | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
| DC Current | 400.0 µA, 4.000 mA, 40.00 mA, 300.0 mA, 10 A |
| AC Current | 400.0 µA, 4.000 mA, 40.00 mA, 300.0 mA, 10 A |
| Resistance | 400.0 O, 40.00 kO, 4.000 MO |
| Continuity | • |
| Diode | • |
| VolTect™ Non-Contact Voltage Detection | – |
| Capacitance | 4.000 µF, 40.00 µF, 400.0 µF, 4000 µF |
| Frequency | 4.000 kHz, 40.00 kHz, 400.0 kHz, 1 MHz |
| Temperature | 1832 °F (1000 °C) |
| Duty cycle | – |
| Logic test | – |
| Inductance | – |
| dBm | – |
| Specifications | |
| DC Voltage ranges | 400 mV, 4 V, 40 V, 400 V, 1000 V |
| DC Voltage accuracy | All ranges: ± (0.7 % rdg + 1 dgt) |
| DC Voltage resolution | 100 µV |
| DC Voltage input impedance | 10 MO |
| AC Voltage (45 Hz to 500 Hz) ranges | 400 mV, 4 V, 40 V, 400 V, 750 V |
| AC Voltage (45 Hz to 500 Hz) accuracy | 4 V Range, 200 Hz to 500 Hz: ± (2.0 % rdg + 4 dgts)
All other ranges: ± (1.5 % rdg + 4 dgts) |
| AC Voltage (45 Hz to 500 Hz) resolution | 100 µV |
| AC Voltage (45 Hz to 500 Hz) input impedance | 10 MO |
| DC Current ranges | 400 µA, 4 mA, 40 mA, 300 mA, 10 A |
| DC Current accuracy | 400 µA to 300 mA ranges: ± (1.0 % rdg + 1 dgt)
10 A range: ± (2.0 % rdg + 3 dgts) |
| DC Current resolution | 0.1 µA |
| DC Current voltage burden | 400 µA range: 1 mV/µA, 4 mA range: 100 mV/1 mA, 40 mA range: 12 mV/1 mA
300 mA range: 4 mV/1 mA, 10 A range: 100 mV/1 A |
| AC Current (45 Hz to 500 Hz) ranges | 400 µA, 4 mA, 40 mA, 300 mA, 10 A |
| AC Current (45 Hz to 500 Hz) accuracy | 400 µA to 300 mA ranges: ± (1.5 % rdg + 4 dgts)
10 A range: ± (2.5 % rdg + 4 dgts) |
| AC Current resolution | 0.1 µA |
| AC Current voltage burden | See DC Current |
| Resistance ranges | 400 O 40 kO 4 MO |
| Resistance accuracy | 400 Oand 40 kO ranges: ± (1.0 % rdg + 4 dgts)
4 MO range: ± (1.2 % rdg + 4 dgts) |
| Resistance resolution | 100 mO |