null

Amprobe ALC-110 leakage current clamp

Amprobe

(No reviews yet) Write a Review
MSRP: $930.36
$723.53
(You save $206.83 )
SKU:
ALC-110
UPC:
095969860116
Availability:
IN STOCK
Weight:
4.00 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added

Product Overview

Amprobe ALC-110 Leakage Current Clamp

Product Highlights

Prevent unplanned downtime by detecting leakage currents with the ALC-110 Leakage Current Clamp. Rated CAT III 600 V to ensure electrical safety, the ALC-110 is designed to resist external magnetic fields for highly accurate readings. Features TRMS, a mechanical jaw lock, max readings and hold functions, highest resolution of 0.001 mA (measure up to 60 A), broad frequency range (15 Hz to 1 kHz), selectable filters (low pass, appliance, no filter), selectable limits (0.25 mA, 0.5 mA, 3.5 mA, 10 mA, 12 mA) and a battery-saving design.

  • Measure:
      • Earth and differential leakage currents
      • Leakage currents through the earth (PE) conductor
      • Appliance current consumption without interruptions to the circuit
  • Trace the source of earth leakage currents
  • Identify intermittent GFCI trips without switching equipment off
  • Check a system for an electrical break of insulation where current is flowing to the ground
  • For use where industrial leakage current testing is required

What’s Included

  • ALC-110
  • 2 x AAA batteries
  • Soft carrying case

Resources

Datasheet »
Product Manual »

Specifications

Features
Low frequency magnetic fields ≤ 30 A/m, operating class 2 @ IN : 3.500 mA to 600.0 mA / 40 Hz to 1 kHz
Measurement category CAT III 600 V
True-rms Yes
AC frequency 15 Hz to 1 kHz
Low pass filter 50 – 60 Hz, for appliance measuring acc. EN61557-16 amendment A, no filter
Limit judgement 0.25 mA, 0.5 mA, 3.5 mA, 10 mA, 12 mA
Jaw opening 1.2 in (30 mm) max.
Jaw locking Yes
Backlight function Yes
Overload protection 60 A
Auto power off Idle 20 minutes
Auto ranging Yes
Max hold Yes
Data hold Yes
Complies with IEC/EN 61557-13 Yes
Built according IEC/EN 61010-2-032 Yes

 

General Specifications
Display Digital: 6000 counts, updates 5/sec
Range Auto ranging
Over range indication OL or -OL
Operating temperature 32 °F to 86 °F (0 °C to 30 °C), ≤ 80% RH
86 °F to 104 °F (30 °C to 40 °C), ≤ 75% RH
104 °F to 122 °F (40 °C to 50 °C), ≤ 45% RH
Operating altitude ≤ 2000 m
Storage temperature -4 °F to 140 °F (-20 °C to 60 °C)
Pollution degree 2
Temperature coefficient 0.1 x (specified accuracy) / °C (<21 °C, <25 °C)
Vibration requirement acc. IEC 61557-1 clause 4.10
Drop proof 4 ft (1.2 m)
Battery 2 x batteries 1.5 V IEC LR03 AAA
Battery life 60 hours typical
Safety compliance IEC/EN 61010-1, IEC/EN 61010-2-030, IEC/EN 61010-2-032, IEC/EN 61557-13
EMC compliance IEC/EN 61326-1, IEC/EN 61326-2-2
Dimensions (H x W x L) 8.7 x 3.5 x 1.8 in (221 x 89 x 48 mm)
Weight 0.9 lb (410 g) with batteries installed

 

Reviews

(No reviews yet) Write a Review